Industrial / Energy Fluids

XCELTHERM® TLX Cleaner

“Super” cleaning agent for systems with that require removal of heavily degraded fluid that has caused excessive carbon and sludge. This low temperature cleaning leaves the system with a bare metal finish on internal piping in only one day. Drain, flush and refill the system to return it to full efficiency.

Advantages:

  • Replace 10% of system volume with Xceltherm® TLX
  • 99% effectiveness at 125°F for 8 hours
  • For excessive carbon/sludge removal
  • Compatible with all common materials of construction
  • System flush required before heat transfer fluid replacement
  • Typical Properties

    Key Temperatures
    Maximum Bulk Operating Temperature 125°F 51.7°C
    Flash Point (PMCC)(ASTM D93)(min) 460.4°F 238°C
    Pour Point (ASTM D97) -38.2°F -39°C
    Pumpability, at 2,000 mm2/s (cSt) 48.2°F 9°C
    Pumpability, at 300 mm2/s (cSt) 77°F 25°C
    Normal Boiling Point, 10% fraction >572°F >300°C
    Physical Properties
    Appearance Slightly turbid liquid
    Odor Faint amine
    Density at 25°C (77°F), pounds/gallon 7.26
    Specific Gravity, at 25°C (77°F) range (typical) 0.87
    Kinematic Viscosity at 40°C (104°F) (ASTM D445) 19-40 cSt
    Kinematic Viscosity at 100°C (212°F) (ASTM D445) 5.0-7.0 cSt
    pH (10% in IPA/Water)(max) 10.0
  • Engineering Properties

    Key Operating Temperatures
    Maximum Bulk Operating Temperature 125°F 51.7°C
    Flash Point (PMCC)(ASTM D93)(min) 460.4°F 238°C
    Pour Point (ASTM D97) -38.2°F -39°C
    Pumpability, at 2,000 mm2/s (cSt) 48.2°F 9°C
    Pumpability, at 300 mm2/s (cSt) 77°F 25°C
    Normal Boiling Point, 10% fraction >572°F >300°C
    Physical Properties
    Appearance Slightly turbid liquid
    Odor Faint amine
    Density at 25°C (77°F), pounds/gallon 7.26
    Specific Gravity, at 25°C (77°F) range (typical) 0.87
    Kinematic Viscosity at 40°C (104°F) (ASTM D445) 90-100 cSt
    Kinematic Viscosity at 100°C (212°F) (ASTM D445) 5.0-7.0 cSt
    pH (10% in IPA/Water)(max) 10.0
    * Data represents typical laboratory samples and are not guaranteed for all samples