Key Operating Temperatures | XCELTHERM® SX800 | ||
Bulk Operating Temperature, maximum | 400°C | 750°F | |
Maximum Film Temperature | 427°C | 800°F | |
Pour Point | -60°C | -76°F | |
Flash Point (Pensky Martens Closed Cup) (ASTM D93) | 162°C | 324°F | |
Flash Point by Cleveland Open Cup (ASTM D92) | 177°C | 350°F | |
Fire Point by Cleveland Open Cup | 193°C | 380°F | |
Autoignition Temperature | 385°C | 725°F | |
Physical Properties | XCELTHERM ® SX800 | ||
Appearance | Clear, colorless | ||
Odor | Characteristic | ||
Composition | Polydimethylsiloxane | ||
Kinematic Viscosity, mm 2 /s (cSt)
at 25°C (77°F) at 40°C (104°F) at 100°C (212°F) |
9.8
7.5 3.40 |
||
Average Molecular Weight | 1250 g/mol | ||
Moisture Content, maximum | 100 ppm | ||
Density at 25°C (77°F) | 936 kg/m 3 | (7.76 lbs/gal) | |
Specific Gravity at 25°C/25°C (77°F/77°F) | 0.93 | ||
Coefficient of Thermal Expansion at 200°C (392°F) | 0.00098/°C | 0.00054/°F | |
Refractive Index at 25°C (77°F) | 1.399 | ||
Dielectric Constant at 100 cycles at 23°C (73.4°F) | 2.68 | ||
Acid Number | 0.00 mg∙KOH/g | ||
Viscosity - Temperature Coefficient | 0.56 | ||
Heat of Combustion | 28,659 kJ/kg | 12,300 BTU/lb | |
Vapor Pressure at 600°F | 596 kPa | 86.5 psia | |
Critical Temperature | 367°C | 692°F | |
Critical Pressure | 10.8 atm | 10.9 bar | |
Critical Volume | 0.0032 m3/kg | 0.0515 3/lb | |
Specific Heat at 25°C (77°F) | 1,507 J/(kg-K) | 0.36 BTU/(lb-°F) | |
Specific Heat at 100°C (212°F) | 1,658 J/(kg-K) | 0.396 BTU/(lb-°F) | |
Thermal Conductivity at 40°C (104°F) | 0.14 W/(m-K) | 0.081 BTU/(hr- -°F) | |
Thermal Conductivity at 100°C (212°F) | 0.12 W/(m-K) | 0.0687 BTU/(hr- -°F) | |
Data represents typical laboratory samples and are not guaranteed for all samples. | |||
XCELTHERM® is a registered trademark of Radco Industries, Inc. | |||
© 2024 Radco Industries, Inc. | All rights reserved |
°C | °F | cP | mm 2/s (cSt) | kg/m 3 | lbs/ft 3 | J/g-K | BTU/lb-°F | W/m-K | BTU/ft-hr-°F | kg/cm 2 | psia |
---|---|---|---|---|---|---|---|---|---|---|---|
-40 | -40 | 60 | 61 | 991 | 61.87 | 1.506 | 0.3597 | 0.1468 | 0.0848 | ||
-20 | -4 | 29 | 30 | 975 | 60.89 | 1.540 | 0.3678 | 0.1428 | 0.0825 | ||
0 | 32 | 16.1 | 16.9 | 960 | 59.91 | 1.574 | 0.3760 | 0.1388 | 0.0802 | 0.00 | 0.00 |
20 | 68 | 10.1 | 10.8 | 944 | 58.93 | 1.608 | 0.3841 | 0.1348 | 0.0779 | 0.00 | 0.00 |
40 | 104 | 6.9 | 7.5 | 928 | 57.95 | 1.642 | 0.3922 | 0.1308 | 0.0756 | 0.00 | 0.02 |
60 | 140 | 5.0 | 5.5 | 913 | 56.97 | 1.676 | 0.4003 | 0.1268 | 0.0733 | 0.01 | 0.10 |
80 | 176 | 3.8 | 4.2 | 897 | 55.99 | 1.710 | 0.4084 | 0.1228 | 0.0710 | 0.02 | 0.32 |
100 | 212 | 3.0 | 3.4 | 881 | 55.01 | 1.744 | 0.4166 | 0.1188 | 0.0686 | 0.06 | 0.83 |
120 | 248 | 2.4 | 2.8 | 865 | 54.03 | 1.778 | 0.4247 | 0.1148 | 0.0663 | 0.13 | 1.80 |
140 | 284 | 1.99 | 2.4 | 850 | 53.05 | 1.812 | 0.4328 | 0.1108 | 0.0640 | 0.24 | 3.46 |
160 | 320 | 1.68 | 2.02 | 834 | 52.07 | 1.846 | 0.4409 | 0.1068 | 0.0617 | 0.43 | 6.08 |
180 | 356 | 1.44 | 1.77 | 818 | 51.09 | 1.880 | 0.4490 | 0.1028 | 0.0594 | 0.70 | 10.01 |
200 | 392 | 1.25 | 1.57 | 803 | 50.11 | 1.914 | 0.4572 | 0.0988 | 0.0571 | 1.10 | 15.62 |
220 | 428 | 1.10 | 1.41 | 787 | 49.13 | 1.948 | 0.4653 | 0.0948 | 0.0548 | 1.64 | 23.38 |
240 | 464 | 0.98 | 1.27 | 771 | 48.15 | 1.982 | 0.4734 | 0.0908 | 0.0525 | 2.37 | 33.78 |
260 | 500 | 0.88 | 1.16 | 756 | 47.17 | 2.016 | 0.4815 | 0.0868 | 0.0502 | 3.33 | 47.39 |
280 | 536 | 0.79 | 1.07 | 740 | 46.19 | 2.050 | 0.4896 | 0.0828 | 0.0478 | 4.56 | 64.83 |
300 | 572 | 0.72 | 1.00 | 724 | 45.21 | 2.084 | 0.4978 | 0.0788 | 0.0455 | 6.10 | 86.80 |
320 | 608 | 0.66 | 0.93 | 709 | 44.23 | 2.118 | 0.5059 | 0.0748 | 0.0432 | 8.02 | 114.04 |
340 | 644 | 0.60 | 0.87 | 693 | 43.25 | 2.152 | 0.5140 | 0.0708 | 0.0409 | 10.36 | 147.36 |
360 | 680 | 0.55 | 0.82 | 677 | 42.27 | 2.186 | 0.5221 | 0.0668 | 0.0386 | 13.19 | 187.66 |
380 | 716 | 0.51 | 0.78 | 661 | 41.29 | 2.220 | 0.5302 | 0.0628 | 0.0363 | 16.58 | 235.87 |
400 | 752 | 0.48 | 0.74 | 646 | 40.31 | 2.254 | 0.5384 | 0.0588 | 0.0340 | 20.60 | 293.01 |
Data represents typical laboratory samples and are not guaranteed for all samples. | |||||||||||
XCELTHERM® is a registered trademark of Radco Industries, Inc. | |||||||||||